Typical applications
Load or unload your CompreCells for use in CompreDrive or CompreFrame, or use the ComPrep directly as preparation and pressure frame. Directly connect a potentiostat.
Pre-pressing of powder materials in CompreCells in a glove box
Easy and reliable removal of pressed pellets from CompreCells
EIS or cycling of CompreCells under pressure in temperature chambers
Selected views and impressions
Detailed Description
The ComPrep is compatible with the CompreCell 6/12 and the CompreCell 6/12-DP as well as the three electrode options.
It is a manually operated pressure frame that comes with a torque wrench. The combination of a high-precision trapezoidal spindle and bearing bronze ensures a reliable and reproducible torque-based force application.
The optimized footprint and the compliance temperature range makes it the ideal solution for testing of many cells in parallel.
As a single unit, it fits every budget.
The electrochemical device (cycler, potentiostat, impedance analyzer) can directly be connected to the ComPrep and the CompreCell using banana connectors.
Technical Details
- Maximum applicable force onto measuring cells:
Fmax: 23 kN
- Torque needed for max. force:
for 23 kN: 40 Nm
- Force needed for 23 kN at lever:
for 23 kN at lever: 200 N
- Temperature range (environment) during operation (ComPrep in climate chamber):
Toperation/CompreFrame = -40 °C to +100 °C when being operated in climate chamber
- Temperature range during storage:
- Relative humidity range during operation and storage:
0 to 80% (non-condensing)
- Atmosphere during storage:
non-corrosive
- Rated dimensions (ComPrep):
25 x 14 x 10 cm (L x W x H) (30 x 14 x 27 cm with lever and spindle)
- Total weight:
approx. 4,4 kg
- Connectors:
both 2 mm and 4 mm female banana
- Saving spaces:
Stackable – functional in both vertical and horizontal orientations.
Key Data
- Art. No.:
840104141
- Essential features at a glance:
- High quality setup for solid-state research
- Compatibility with all test cells with prefix CompreCell
- Airtight measuring cells allow for the handling of sensitive samples outside of a glovebox
- Large range of applicable force up to 23 kN
- Large range of sample temperature from -40 °C up to 100 °C (in climate chamber)
- Universal compatibility with all potentiostats/galvanostats/battery cyclers